Osburn 1600 Wood Stove - Black Door - OB01613
With its perfect balance between power, efficiency and cleanliness, the Osburn 1600 wood stove is truly unique. Able to heat up to 1,800 square feet* with a performance of 65,000 BTU/hr it is also environmentally friendly with emissions as low as 0.87 g/hour, well below EPA standards. No compromise is necessary with the 1600 - you choose a pedestal or cast iron legs, then you select a black door, a gold plated door or a brushed nickel plated door. Whatever your choice, you'll have a beautifully balanced wood stove.
Osburn 1600:
Model # : OB01613
APPLIANCE PERFORMANCE (1)
Fuel type: Dry cordwood
Recommended heating area (sq.ft.): () 500 - 1,800
Overall firebox volume: 2.0
Maximum burn time: () 6 h
Maximum heat output (dry cordwood): (2) 65,000 BTU/h (19.0 kW)
Overall heat output rate (min. to max.): (2) (3) 11,800 BTU/h (3.5 kW) to 42,400 BTU/h (12.4 kW)
Average overall efficiency (EPA cribs / Douglas fir): (3) 68.0 % (HHV) (4) 73.0 % (LHV) (5)
Average overall efficiency (dry cordwood): (3) N.A. (HHV) (4) N.A. (LHV) (5)
Optimum efficiency: (6) (7) 80 %
Average particulate emissions rate: (8) 4.4 g/h
Average CO: (9) N.A.
(1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
(2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
(3) As measured per CSA B415.1-10 stack loss method.
(4) Higher Heating Value of the fuel.
(5) Lower Heating Value of the fuel.
(6) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
(7) Optimum overall efficiency at a specific burn rate (LHV).
(8) This appliance is officially tested and certified by an independent agency.
(9) Carbon monoxyde.
Click to see the Osburn 1600 Owners Manual